Paradigm Flow Modulator and Shift Flow Splitter: Improve GC peak capacity without sacrificing accuracy
Greatly expand chromatographic peak capacity across entire volatility ranges with the Paradigm Reverse Fill-Flush (RFF) Modulator. Reverse fill-flush modulators deliver comprehensive two-dimensional gas chromatography separation by filling a fixed volume sample loop with primary column effluent, before rapidly flushing the contents out of the sample loop and onto an orthogonal secondary stationary phase. Complete transfer of analytes between the respective stationary phases (comprehensive GCxGC) ensures excellent method repeatability and quantitation.
Features
- Cryogen-Free modulation for GCxGC-FID or simultaneous TOFMS/FID acquisition when paired with the Shift flow splitter
- Unique backpressure-controlled loop filling which permits method flexibility without the hassle of restrictor or bleedline changes
- Column and loop fittings are readily accessible with standard wrench
ChromaTOF Makes Modulation Simple
Paradigm does away with complicated offline flow calculators. The integrated ChromaTOF software features a simple user interface that automatically performs the necessary calculations for users. The resulting methods are guaranteed to feature complete analyte transfer, excellent peak shapes, and excellent chromatographic resolution.
ChromaTOF Software identifies method calculation improvements for RFF modulation
A Shift Forward in Chromatographic Analyses
The Shift flow splitter is simple in design and appearance, but Shift’s novel splitting mechanism delivers long-sought functionality for complex sample characterization. Unlike traditional splitters, Shift maintains a constant split ratio between the MS and FID throughout the GC oven program. The result is unparalleled quantitative accuracy with minimal internal standardization required, greatly simplifying analyte and group-type quantitation for GC and GCxGC analyses.
Close-up on the Shift Flow Splitter installed in a GC oven
Features
- Novel chromatography splitter featuring two channels of pressure assistance
- Designed to work with the high flow rates needed for RFF modulation (approximately 20 mL/min)
- Maintains constant split ratio between MS and FID throughout an entire run, even during oven temperature ramps
Software-optimized Detector Performance
ChromaTOF automatically optimizes the flow rate directed to the TOFMS and FID for proper peak shapes and balanced sensitivity.
ChromaTOF Software automatically optimizes flow rates